Remote Commands
C-70 GB1400 User Manual
disp_select [total || window || test]
Display Select. Selects the total, window, or test display mode. The display mode
determines which BER and bit error results are shown in the top-middle, and top-right
fields respectively of the display.
Min. Abbr. dis
Arguments total: selects the Totalize display mode, Totalize Error
Rate/Total
window: selects the Window display mode, Window Error Rate/
Total
test: selects the Test display mode, Test Error Rate/Total
Example disp_select test
disp_select?
Display Select Query. Returns a character string that indicates the current display
mode of the Analyzer.
Min. Abbr. dis?
Returns [total | window | test]
Example disp_select? (command)
DISP_SELECT TEST (response)
error_reset
Error Reset. This command resets the Totalize and Window measurement processes.
This does not affect Test results.
Min. Abbr. er
Arguments none
Example error_reset