Remote Commands
GB1400 User Manual C-59
data_del_up [v] and
data_del_dn [v]
Data Delay Up/Down. This command pair is used to increment (data_del_up) or
decrement (data_del_dn) the current DATA input delay by v seconds. Note that v is
expressed as a real number with an exponent and is in the range of 0.1 to 3.99 nSec in
0.005 nSec steps.
Min. Abbr. data_del_u
data_del_d
Argument v <NR3>, 0.1E-9 to 3.99E-9 in 0.005E-9 steps
Example data_del_up 0.02E-9
data_del_dn 0.10E-9
data_delay [v]
Data Delay. Sets the Analyzer DATA input delay to any value from 0.0 nS to 3.99 nS in
0.005 nSec steps. . Note that v is expressed as a real number with an exponent of -9.
Min. Abbr. data_dela
Argument v: 0.00E-9 to 3.99E-9 in 0.005E-9 steps
Example data_delay 1.62E-9
data_delay?
Data Delay Query. Returns the current value of the Analyzer DATA input delay setup
parameter.
Min. Abbr. data_dela?
Returns <NR3>
Example data_delay? (command)
DATA_DELAY 1.62E-9 (response)