Remote Commands
C-36 GB1400 User Manual
Generator Commands
The following commands are found only in the Generator command set.
Clock Source and Frequency Setup Commands
clock_freq [v]
Clock Frequency. Sets the clock frequency to a value [v], specified in Hz, over the
range of 1 MHz to 1405 MHz in steps of 1kHz.
Min. Abbr. clock_f
Arguments v <NR3>, in the range 1.000E+6 to 1405.000E+6 in steps
of 0.001E+6.
Example clock_freq 622.000E+6.
clock_freq?
Clock Frequency Query. Returns the current Generator clock frequency setting.
Min. Abbr. clock_f
Returns <NR3>
Example clock_freq? (command)
CLOCK_FREQ 0.150E+6 (response)
clock_memory?
Clock Memory Query. Returns the contents of all ten frequency memory locations.
The response will be 10 message units separated by semi-colons ";", and will contain the
memory location and frequency.
Returns <NR1 Numeric>
<NR3 Numeric>