9-529DIOD-DS1 (DS1 DIOD Trunk)
9
2053 ABORT At least one of the following errors is found on the DS1 circuit pack:
■ 1281—Loss of signal
■ 1793—Blue Alarm
■ 2049—Red Alarm
■ 2305—Yellow Alarm
■ 1537—Hyperactivity
Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
FAIL The trunk cannot be seized for an outgoing call.
1. Verify that the Trunk Type field on the trunk administration screen form
matches the trunk type administered on far end switch.
2. Look for UDS1-BD errors in Hardware Error Log. If present, refer to the
UDS1-BD (DS1/UDS1 Trunk Circuit Pack) Maintenance documentation.
3. Retry the test at 1-minute intervals for a maximum of 5 times.
PASS The trunk can be seized for an outgoing call.