
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1291PMS-PRNT/JNL-PRNT (PMS Printer Link)
9
Error Log Entries and Test to Clear Values
Notes:
a. Craft busied out the Journal Printer Link. The link is torn down. Enter
release
command to restore the link.
b. Link Retry Test (#215) fails. Physical link cannot be set up, usually
because of hardware problems such as power off or cable disconnect.
Refer to “Procedures for Restoring the PMS Printer Link” above.
c. Physical link cannot be set up, usually because of hardware problems
such as power off or cable disconnect. The PMS Printer Link physical link
is down due to the following causes: cable to the printer device is
disconnected, the printer device is powered off, or the data extension
where the printer device connects to has been busied out. Check the
connectivity of wire and cable among wall jacket, data module, and the
printer device. Enter status data <extension> and verify that the data
extension of the printer device is in the in-service/idle state. If the data
extension is not available, then refer to the ‘‘Procedures for Restoring the
PMS Printer Link’’ above.
d. Link idle timer; link comes down. This indicates that the printer device is in
an off-line state, for example, paper jam or paper out. Check the printer
device and act promptly to put it back to on-line state. Enter test journal
wakeup-log|pms-log command to set up the printer link.
Table 9-507. PMS-PRNT/JNL-PRNT Link Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures. Both PMS Printer and Journal
Printer are administered to the same extension, and the printer is not connected. Refer to the
Procedures for Restoring the PMS Printer Link
above for resolution.
0 Any Any Any test journal
wakeup-log|pms-log sh
18 (a) 0 busyout journal
wakeup-log/pms-log
WARNING OFF release journal
wakeup-log|pms-log
257 (b) Any Link Retry Test(#215) MINOR/
2
WARNING
2. Minor alarms may be downgraded to Warning alarms based on the value used in the set options
command.
OFF test journal
wakeup-log|pms-log l
513 (c) Any test journal
wakeup-log|pms-log
769 (d)