A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1808TSC-ADM (Administered Temporary Signaling Connections)
9
The two administration commands for ADM TSCs are as follows:
add signaling group
number
change signaling group
number
The two maintenance commands for ADM TSCs are as follows:
test tsc-administered signaling group
number [/tsc index]
status tsc-administered signaling group
number [/tsc index]
Error Log Entries and Test to Clear Values
Note:
a. There is no Test to Clear Value for error types 3840-3967. These error
types provide the following additional data that may prove useful when
tracking down problems.
Any of these errors indicates that a TSC Heartbeat Inquiry Test was run on
an active far-end Administered TSC from the switch. Upon receiving the
heartbeat message, the network communicated that the call was unable
to complete. As a result, the error was logged. Check the signaling group
status of the D-channel or D-channel pair via the
status signaling-group
<group>
command for the Administered TSC. Check the status of the
Administered TSC via the
status tsc-administered
command. Also check
the administration of the Administered TSC on the switch.
This error may only be affecting service for some DCS customers. Upon
receipt of this error condition, the switch will tear down and re-establish
the ADM TSC within 20 minutes.
Table 9-675. ADM TSC Error Log Entries
Error Type Aux Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
3840-3967 (a) tsc index # test tsc-administered