Maintenance Object Repair Procedures
9-963ISDN-TRK (DS1 ISDN Trunk)
9
NPE Crosstalk Test (#6)
The NPE Crosstalk Test verifies that this port’s NPE channel talks on the selected
time slot and never crosses over to time slots reserved for other connections. If
the NPE is not working correctly, one-way and noisy connections may be
observed. This test is usually only part of a port’s long test sequence and takes
about 20 to 30 seconds to complete.
NOTE:
The TN464C/D UDS1 circuit pack has one SCOTCH-NPE chip instead of
several NPE chips.
Table 9-368. System Technician-Demanded Tests: DS1-BD
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive, ND = Non-destructive
NPE Crosstalk Test (#6) X ND
Conference Circuit Test (#7) X ND
Audit and Update Test (#36) X X ND
Signaling Link State Check Test (#255) X X ND
Service State Audit Test (#256) X X ND
Call State Audit Test (#257) X X ND
ISDN Test Call Test (#258) X ND
Continued on next page