
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-734DUPINT (Duplication Interface Circuit Pack)
9
b. A local DUPINT FIFO overflow condition has been reported. If this alarm
cannot be cleared by replacing the active Duplication Interface circuit
pack, escalate the problem.
c. In-line errors have been reported from the DUPINT driver. If this alarm
cannot be cleared by replacing the active Duplication Interface circuit
pack, escalate the problem.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the
Control Register Test
for example, you may also
clear errors generated from other tests in the testing sequence.
51 The Active DUPINT Reset Test failed because the HFAIL bit stayed set
after reset.
52 The Active DUPINT Reset Test failed because the state of health could
not be restored after the reset.
55 The Active DUPINT Reset Test failed because shadowing could not be
turned off after the board was successfully reset.
Aux
Data Cause of Error
23 DUPINT driver suicide
24 DUPINT driver loss of interrupt path
27 DUPINT driver no handshake path for processes
28 DUPINT driver no handshake path for drivers
29 DUPINT driver no control path
30 DUPINT driver main receive failed
Aux
Data Cause of Error