DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1084MODEM-PT (Modem Pool Port)
9
Error Log Entries and Test to Clear Values
Table 9-430. Modem Pool Port Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
18 0 busyout UUCSS WARNING OFF release port UUCSS
130
2
2. This error type indicates that the circuit pack has been removed or has been insane for more than 21
minutes. To clear the error, reinsert or replace the circuit pack.
None WARNING ON test port UUCSSpp sh
257 Conversion Resource Loop
(#98)
MINOR ON test port UUCSS s r 3
513 Modem Conference (#97) MINOR ON test port UUCSS l r 3
769 Modem NPE Crosstalk (#96) MINOR ON test port UUCSS l r 3