DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-764ETH-PT (Control LAN Ethernet)
9
Error Log Entries and Test to Clear Value
Notes:
a.
Error Type 1
: Ethernet Local Looparound Test (#1278) failed.
1. Test the port (test port UUCSSpp long).
2. Refer to repair procedures for Test #1278.
Table 9-295. ETH-PT Error Log Entries
Error Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port UUCSSpp s
1 (a) 0 Ethernet Local
Looparound
Test (#1278)
MINOR ON test port UUCSSpp l r 3
513 (b) 0 Link Integrity Inquiry
(#1282)
MINOR OFF test port UUCSSpp r 2
769 (c) 0 Invalid Frame Error WNG OFF
1281 (d) 0 Far-end Disconnect
1537, 1538
(e)
See
note
Session Status Test
(#1286)
MINOR OFF
1793-1920
(f)
See
note
Socket failure
2305-2560
(g)
See
note
Session Down error
Session #s 1-256
2561-2816
(g)
See
note
Session Down error
Session #s 257-512
3329 (h) See
note
TCP/IP Ping Test
(#1281)
WNG OFF
Continued on next page