A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1418SNC-LINK (Switch Node Clock Link)
9
SNC-LINK (Switch Node Clock Link)
The SNC-LINK maintenance object reports errors in communications between
the active Switch Node Clock and Switch Node Interfaces over the serial channel
(aux data 1) and the TPN link (aux data 2). SNC-LINK errors are described on the
following pages. For a complete description of SNCs and SNIs, including circuit
pack replacement instructions, see maintenance objects SNI-BD and SNC-BD.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1. UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (10 or 12).
Full Name of MO
SNC-LINK MINOR test board UUCSS s SNC Link