A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-16ADX8D-PT (AUDIX Digital Port)
9
Error Log Entries and Test to Clear Values
Notes:
a. The user may experience a noisy port or link. This is an off-board problem
that is detected by the port circuit. If this problem exists, replace the
circuit pack (see caution at the beginning of this section). Once the
problem is resolved, the alarm is retired after a predetermined time.
b. At least 15 off-board problems have been detected with the link to the
voice port. When an error with the link is detected, an on-board counter is
incremented. Also see Note (a).
c. This is an internal type error that occurs when an audit request fails.
d. The port is busied-out by command. You can release the port via the
release port UUCSSpp command.
Table 9-6. DEFINITY AUDIX Digital Port Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1(a) 40987 None WARNING OFF
1(b) 1 to
20
None WARNING OFF
15(c) Any None
18(d) 0 busyout port
UUCSSpp
WARNING OFF release port UUCSSpp
23(e) 0 None WARNING OFF
130(f) None WARNING ON test port UUCSSpp sh
257(g) 40971 None
513(h) Any None
1537(i) 40968 None WARNING OFF
1793 Voice & Ctrl. Local
Loop Test (#13)
MIN/WRN
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
ON test port UUCSSpp l r 3
2049 NPE Crosstalk Test
(#9)
MIN/WRN
2
ON test port UUCSSpp l r 3
2305(j) 40967 None
3840(k) 40965 None
3840(l) 41029 None