DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-210set snc
8
Parameters
set snc
set snc
UUCSS [override]
This command sets which switch node clock (SNC) circuit pack in a given switch
node carrier is active.
NOTE:
This command is valid only on a High Reliability system with a Center Stage
Switch (duplicated SPE, simplex PNC). In this configuration, SNCs are
duplicated on each switch node carrier.
Parameters
set synchronization
This command sets a specific DS1 trunk, tone-clock circuit pack, or ATM switch
as the reference source for system synchronization signals. It is permitted only
after synchronization has been disabled with
disable synch
. Any administered
DS1 trunk or
active
tone-clock may be entered with the set command. The DS1
or tone-clock will remain the synchronization reference until either the set
command specifies another circuit pack, or
enable synchronization
is entered.
After an
enable synchronization
, the administered primary or secondary
synchronization source will become the synchronization reference. If no primary
or secondary source is administered, the active tone-clock is used as the
synchronization reference.
NOTE:
This command is not supported when ATM-PNC is enabled.
group#
The signaling group identifier is an administered number assigned to each
signaling group.
override
This qualifier will force execution of the set command regardless of the
health of the standby SNC circuit pack.
Action/ Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
set synchronization
print
init
inads
craft
none none