DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1232PGATE-PT (Packet Gateway Port)
9
Session Status Query Test (#976)
This test is non-destructive.
This test determines the state of the sessions on the X.25 Access Link associated
with the Packet Gateway port.
This test determines if all the sessions associated with the channels using the
X.25 Access Link is up or down. This test passes if the all the sessions are up
and fails otherwise.
2 FAIL The X.25 Access Link is disconnected.
1. Execute the Packet Gateway Port Local Loop-Around Test (#610) and the
Level 1 State Query Test (#613) via the test port UUCSSpp long
command. Consult the repair procedures for these tests.
2. If all tests pass, check far-end switch equipment. Execute the Packet
Gateway Port Remote Loop-Around Test (#611) via the test port
UUCSSpp long command. Consult the repair procedures for this test.
3. If test #611 passes, see the repair procedures for the Packet Control circuit
pack and the Packet Bus.
PASS The X.25 Access Link is connected.
Table 9-492. TEST #976 Session Status Query Test
Error
Code
Tes t
Result Description/ Recommendation
1124 ABORT The X.25 access link associated with this Packet Gateway Port is not enabled.
1. Check if the X.25 access link is enabled for this Packet Gateway Port. If the
‘‘enable’’ field on ‘‘display communication-interface link’’ form is ‘‘n’’ for the
link entry which contains the data module extension associated with the
Packet Gateway Port, then the X.25 access link is not enabled. Set the field
to ‘‘y’’ using change communication-interface link command and repeat
the test. This is a NORMAL abort.
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 9-491. TEST #614 Link Status Test — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page