DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1645TAPE
9
Tape Firmware Error Counters Read
and Clear Test (#812)
The Host Adapter firmware is constantly running background tests on each of its
devices. When an error is detected by one of these background tests, the
appropriate counter in the host adapter dual port RAM is incremented. The Tape
Firmware Error Counters Read and Clear Test requests that the firmware return
these errors to the software and clear the area in dual port RAM. If any counter is
non-zero, the software then increments the appropriate software counter. The 16
errors reported by the firmware are:
Unexpected interrupt from the SCSI Bus Interface Controller Chip (SBICC)
SBICC timed out during SCSI command
Error interrupt from the Direct Memory Access Controller (DMAC)
DMAC timeout without issuing interrupt
Tape self-test failed
1
FAIL The audit of the tape directory failed.
1. Verify that a tape cartridge is installed.
2. Perform a backup disk. This may take up to an hour to complete.
3. If the test continues to fail, replace the Tape Cartridge. Wait for the retension
pass to complete and rerun the test. If the test succeeds, issue the backup
disk command.
4. If the test continues to fail, replace the Tape circuit pack.
5. If the test continues to fail, determine if other Tape, Disk, or Host Adapter
tests fail, and if they do, follow the repair procedures for those failures.
PASS The tape directory audit succeeded. Check other results to see if it is operating
correctly.
1. See the MSS Error Actions table at the end of the section on TAPE.
Table 9-619. TEST #811 Tape Audit Test — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page