A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-272status hardware-group
8
Output
If the specified port is administered as a system port, the following fields will be
displayed at the bottom of the screen. See PDATA-PT in Chapter 9
for more
information.
status hardware-group
status hardware-group [print]
Summary information on the active or last hardware group tests will be displayed.
This display includes the number and percentage of maintenance objects tested,
the percentage of tests passed/failed/aborted, the time elapsed since initiating
the hardware group test, the specific hardware group test command (see test
hardware-group command) initiated, and the state (active/canceled/complete) of
the hardware-group test.
Data Ext/Sta
Ext for Stn
DM
The data module’s extension number. For DTDMs, the connected
station extension is shown instead.
Port/Channel
Number
The location of the port connected to the data module. For data
channels, the channel number is shown instead.
Service
State
The operational state of the data-module:
in-service/idle
The data module is connected but not in use.
in-service/active
The data module is connected and in use.
out-of-service
The data module has been removed from service.
CF Destination
Ext
The call-forwarding destination, if any, of the port.
Maintenance
Busy
Whether the port is busied out for testing.
Connected Ports
Locations of ports to which the data module is currently
connected.
Associated
PDATA Port
The location of a port on a TN553 Packet Data Line circuit pack to
which this data-module port is connected.
Service State
The operational state of the associated PDATA port.
Maintenance
Busy
Whether the PDATA port is busied out for testing.