DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-210ATM-EI (Expansion Interface Circuit Pack)
9
ATM Cross Talk Test (#1298) (TN2305/6 only)
This test is non-destructive. The ATM board Cross Talk test verifies that the
selected TDM bus time slot never crosses over to time slots reserved for other
connections. The test also checks for cross connections, where the board talks
to time slots other than those specified. Since this test uses many system
resources (TDM time slots, tone generator, tone detector, and others), it runs as a
part of demand test only.
This test fails if either the TDM programmable logic and/or the interface to the
DSP is not operating properly. Failure of these components may result in one-way
or noisy connections. Refer to Figure 9-9
for a schematic of this test.
NOTE:
Note: This test applies only to TN2305 and TN2306 circuit packs.
Figure 9-9. ATM Cross Talk Test #1298 schematic
Table 9-90. ATM Crosstalk Test (#1298)
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-Bus errors. Refer to TDM-BUS to diagnose these errors.
1. If system has no TDM-Bus errors and is not handling heavy traffic,
repeat test at 1-minute intervals for a maximum of 5 times.
Continued on next page
ATM
circuit
pack
PNC mode
iodfatcr AWF 040699
DSP Talker
TDM bus
(PN X)
Tone detector