DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1622SYSAM (Circuit Pack)
9
1379 ABORT System could not determine if testing of remote access port is administered.
1. Check system-parameters maintenance screen for a y in the Test
Remote Access Port field.
2. Retry the command.
2000 ABORT Response to the test request was not received within the allowable time
period. If the system is a High or Critical Reliability configuration and if the
SYSAM circuit pack is on the standby SPE, this abort code may indicate that
the standby SPE is not responding to the handshake message. If this is the
case, the standby SPE maintenance software may take up to two minutes to
indicate that handshake communication with the standby SPE is down. The
ABORT code will then change to 1339 (standby SPE unavailable).
1. Retry the command at 1-minute intervals, a maximum of 3 times.
2034 ABORT The remote access port is busy. A remote user has probably dialed into the
switch.
1. If a remote user is dialed in, remote access line is working. No need to
run test. Use the status logins command to verify that the SYSAM-RMT
port is in use.
2080 FAIL An external modem is administered on a switch with an active TN1648 (prior
to suffix B.)
1. Set the Modem Connection: field on the system-parameters
maintenance screen to internal. (The external modem capability requires
a TN1648 suffix B or later.)
2. Retry the command.
Table 9-613. TEST #912 SYSAM External Modem Present Test — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page