A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-90display errors
8
The following display command will be cancelled and echo “Command aborted”
and exit.
Cancel
System Reboots and the Error and Alarm Logs
The system attempts to save the error and alarm logs to the disk on the
active
SPE when any of the following events take place:
—The
save translation
command is executed.
Translations are saved as part of scheduled maintenance (as
administered on the maintenance-related system parameters form).
A demand or software-escalated system reboot takes place.
The PPN is about to lose all power after having been on battery backup.
Conditions such as unavailability of the MSS can prevent this attempt from
succeeding.
Whenever the system reboots, the error log is restored from the disk on the SPE
that becomes active with the reboot. Since the logs are saved to the disk on the
SPE that was active before the reboot, the versions restored at reboot time may
not be current. This occurs when either:
The attempt to save at reboot did not succeed.
The SPE that is active coming out of the reboot is not the same one to
which the logs were last saved.
In such a case, the logs will not show the errors and alarms that have been
logged since the last time a save was made to the SPE that became active with
the reboot. When looking at errors that precede the last reboot, look for
indications preceding the reboot to determine whether the logs restored at
reboot are complete.
System resets less severe than a reboot rarely affect the error and alarm logs.
NOTE:
If there are SYSTEM errors in the Error Log, use
display initcauses
to
obtain additional information. Information that could not be logged during a
system reset may be found here.
Parameters
high-resolution This option specifies an error report with high resolution time stamps
for the first occurrence and last occurrence of the error. The high
resolution time stamp includes seconds and a sequence count within a
second. The sequence count starts over for each second.