Toshiba VF-A7 Welding System User Manual


 
F-16
[D.C. braking under normal conditions]
(Forward/reverse DC braking priority control =[OFF])
If  and  > reference frequency : DC injection braking
If  > reference frequency >  : Operation at command frequencies,
If  and  > reference frequency : DC injection braking
If an operation command is entered during D.C. braking : D.C. braking is discontinued to restart the
operation.
[Priority to DC injection braking during forward/reverse operation]
(Forward/reverse run D.C. braking priority control  = (ON))
During normal forward/reverse run( )
Not recognized as a stop command, so that DC injection braking is not active.
If a reverse run (or forward) command is entered during forward run (or reverse)
( ) DC injection braking starts when the frequency set with  exceeds the
reference frequency during deceleration.
If an operation command is entered during D.C. braking priority is given to D.C. braking.
6.8.2 Motor shaft fixing control
 Motor shaft fixing control
Function
This function is useful for preventing the motor shaft from rotating freely or for
preheating the motor.
ON
OFF
time [ ]
: DC injection braking

Output frequency [Hz]
Operating signal (F-CC)
Reference frequency
0
Set frequency


 


Output frequency [Hz]
signal (F-CC)
ON
OFF
Reference frequency
Set frequency


: DC injection braking


signal (R-CC)
ON
OFF



time [ ]