E-8
1) Setting the start, stop and operation frequencies with the operating panel
Title Function Set value
Operation command
Mode selection
(operating panel)
Speed setting mode
selection
(operating panel)
2) To set the start and stop frequencies (forward run, reverse run and free-run stop) by
means of external signals and to set the operation frequency with the control panel
Title Function Set value
Operation command
Mode selection
(Terminal input)
Speed setting mode
selection
(operating panel)
Power
supply
Motor
IM
G/E
CC
F
R
ST
R/L1
U/T1
Control panel
C
C
S/L2
T/L3
V/T2
W/T3
Forward run if ON
Slowdown stop if OFF
Reverse run if ON
Slowdown stop if OFF
Standby if ON,
Coast stop if OFF
RX VI R
R
P
P
II
Motor
IM
G/E
CC
F
R
ST
R/L1
U/T1
Control panel
C
C
The inverter is shipped with
these terminals shorted.
Power
supply
S/L2
T/L3
V/T2
W/T3
RX VI R
R
P
P
II
To save the frequency, press
the Enter key. Then,
and the set frequency are
displayed alternately for a
while.
A
s for the action the moto
r
takes when both the
terminals F and R are
connected at the same time,
you can make selection
between reverse run and a
stop. => Refer to 6.2.2.
To save the frequency,
press the Enter key. Then,
and the set frequency
are displayed alternately for
a while.
[Start/stop]: Connection and disconnection of terminals
F-CC/R-CC (Standby: connection of
terminals ST and CC)
[Speed command]: Set the frequency, using the
key on the control panel.
[Start/stop]: Press the key on the control
panel.
To switch between forward run and reverse run, use
the forward/reverse run selection parameter .
[Frequency ref.]: Set the frequency, using the
key on the operating panel.
RUN STOP