Toshiba VF-A7 Welding System User Manual


 
J-24
Input terminal function setting (1/2)
Positive
logic
Negative
logic
Function
Speed
control
Torque
control
Position
control
V/f
constant
= = = =
Reference
section
0 1 No assignment function / / /
2 3 F: Forward operation command / / /
4 5 R: Reverse operation command / / /
6 7 ST: Standby (Inverse) / / /
8 9 RES: Reset / / /
10 11 S1: Preset-speed #1 /
12 13 S2: Preset-speed #2 /
14 15 S3: Preset-speed #3 /
16 17 S4: Preset-speed #4 /
18 19 Jog run /
20 21 Emergency stop / / /
22 23 DC injection breaking /
24 25 Acc/dec switching #1 /
26 27 Acc/dec switching #2 /
28 29 V/f switching #1 /
30 31 V/f switching #2 /
32 33 Torque limit switching #1 / / /
34 35 Torque limit switching
#2
/ / /
36 37 PID control OFF selection /
38 39 Pattern group #1 /
40 41 Pattern group #2 /
42 43 Pattern group #3 /
44 45 Pattern group #4 /
46 47 Pattern run continuation signal /
48 49 Pattern run trigger signal /
50 51 Forced Jog forward operation /
52 53 Forced Jog reverse operation /
54 55 Reservation area
56 57 Reservation area
58 59 Reservation area
60 61 Reservation area
62 63 Reservation area
64 65 Reservation area
66 67 Reservation area
68 69 Reservation area
7.2.1
: Reservation area. Do not set at these functions.
Sensorless vector/vector with sensor : valid, : invalid