4) Setting the operation mode
An operation mode can be selected for each preset-speed.
Operation mode setting
Title Function Adjustment range
Default setting

Present-speed operation
mode
: Disabled
: Enabled
: Disabled ... Only frequency commands are governed by the preset-speed
command (#1 to #15) entered.
: Enabled ... The direction of rotation, the V/f control mode, the acceleration and
deceleration times and the torque limit can be set individually for each
preset-command.
If you selected “enabled”,the motor runs operation mode setting directions as below
without following terminal F,R.
Operation mode setting
Title Function Adjustment range
Default setting
 
Present-speed
#1 to #15
control mode
+: Forward run
+: Reverse run
+: Selection of acc/dec
switching #1
+: Selection of acc/dec
switching #2
+: Selection of V/f switching #1
+: Selection of V/f switching #2
+: Selection of torque limit
switching #1
+: Selection of torque limit
switching #2
For the settings marked with +, more than one function can be selected at the same time by
entering the sum of the numbers of the desired functions.
Ex.1) (+) + (+) =
By entering , you can activate the reverse run function and the acceleration/deceleration
time #2 function at the same time.
Ex.2) (+) + (+) + (+)=
By entering , you can activate the forward run function and the acceleration/deceleration
time #4 function at the same time.
(Selecting both of acc/dec switching #1 and acc/dec switching #2 means selection
of acceleration/deceleration time #4. This manner is common to V/f pattern and
torque limit.)