Toshiba VF-A7 Welding System User Manual


 
K-2
2) Standard specifications by types (large capacity types)
Item Description
Voltage class 200 V class
Applicable motor [kW]
75 90
Model No. VFA7–
Type 2750P1 2900P1
Output capacity [kVA] (*1)
110 133
Output current [A]
288 350
Output voltage 3-phase 200 to 230 V (Maximum output voltage corresponds to input supply voltage.)
Ratings
Rated overload current
150% for 1 minute, 180% for 0.3 second (*5)
D
y
namic brakin
g
circuit
Built-in type dynamic braking drive circuit is optionally available
Electric
brakin
g
Dynamic braking
resistor
External braking resistor is available optionally
Main
circuit
3-phase 200-230 V, 50/60 Hz
Voltage,
frequency
Control
circuit
Single phase 200-230 V, 50/60 Hz
Power supply
Allowable fluctuation
Voltage: +10%/-15% (*3), Frequency: +/-5%
Protection structure Open type (JEM1030) IP00 (*2)
Cooling system Forced-air cooling
Coating color Munsell 5Y-8/0.5
EMI filter Option to be installed externally
Item Description
Voltage class 400 V class
Applicable motor [kW]
90/110 132 160 220 280
Type VFA7–
Form 4110KP1 4132KP1 4160KP1 4220KP1 4280KP1
Output capacity [kVA] (*1)
160 194 236 320 412
Output current [A]
210 255 310 420 540
Output voltage 3-phase 380-460 V (Maximum output voltage corresponds to input supply voltage.)
Ratings
Rated overload current
150% for 1 minute, 180% for 0.3 second (*5)
D
y
namic brakin
g
circuit
Built-in type dynamic braking drive circuit is optionally available
Electric
brakin
g
Dynamic braking
resistor
External braking resistor is available optionally
Main
circuit
3-phase 380-460 V, 50/60 Hz
Voltage,
frequency
Control
circuit
Single phase 380-460 V, 50/60 Hz
Power supply
Allowable fluctuation
Voltage: +10%/-15% (*3), Frequency: +/-5%
Protection structure Open type (JEM1030) IP00 (*2)
Cooling method Forced-air cooling
Coating color Munsell 5Y-8/0.5
EMI filter Option to be installed externally
(*1): Rated output capacity indicates a value based on the condition that output voltage is 220 V in case of the 200 V class or
440 V in case of the 400 V class.
(*2): The models of 30 kW or higher have neither cover for the wiring hole that has a big aperture nor space for bending
external cables inside the unit. When a protector is installed externally, use an optional cover for the wiring hole.
(*3): Allowable voltage variation is +/-10 % in continuously operation (100 % load)
(*4): Be sure to attach DC reactor (option) for the models: 200V class 75kW or more and 400V class 110kW or more.
(Not necessary for DC input.)
(*5): This regulation is overload value from the stop state at ambient temperature state within regulation value.
3) Comparison between small/medium capacity types and large capacity types in specifications (different points only)
Small/medium capacity type Large capacity type
Item
VFA7-2004PL 2150P
VFA7-4007PL 4150PL
VFA7-2185P 2550P1
VFA7-4185P 4750P1
VFA7-2750P1,2900P1
VFA7-4110KP1 4280KP1
1. Rated overload
current
150 % for 2 minutes
215 % for 0.5 second
150 % for 2 minutes
215 % for 0.5 second
150 % for 1 minutes
180 % for 0.3 second
2. PWM carrier
frequency
Default setting: 12 kHz
Adjustable between 0.5 and 15 kHz
Default setting: 12 kHz
200 V class 37,45 kW type: 8 kHz
200 V class 55 kW type: 2.2 kHz
400 V class 37-55 kW type: 8 kHz
400 V class 75 kW type: 2.2 kHz
Adjustable between 0.5 and 15 kHz
2550P1,4750P1:
Adjustable between 0.5 and 8 kHz
Default setting: 2.2 kHz
Adjustable between 0.5 and 5 kHz
3.
Acceleration/deceleration
time
(default setting)
10 seconds
30 seconds
4750P1:60 seconds
60 seconds