F-46
Parameter setting
Title Function Adjustment range Default setting
Selection of power running
torque limit #1
:
VI(voltage)
/
II(current)
:
RR(volume
/
voltage)
:
RX(voltage)
:
RX2(voltage)(optional)
:
Power running torque limit #1
[%], :
Invalid
Selection of regenerative
torque limit #1
:
VI(voltage)
/
II(current)
:
RR(volume
/
voltage)
:
RX(voltage)
:
RX2(voltage)(optional)
:
Regenerative torque limit #1
[%], :
Invalid
Note) If the value set with (stall prevention level) is smaller than the torque limit, then the value set
with acts as the torque limit.
b) Limiting the torque with external signals
The torque limits can be changed arbitrarily by means of external signals.
[External signals]
Voltage signals
Current signals
With these parameters, you can set 4 patterns of positive torque limits and 4 patterns of
negative torque limits. Refer to 7.2 for the setting for switching from the terminal board.
Power running torque limit #1 Regenerative torque limit #1
Power running torque limit #2 Regenerative torque limit #2
Power running torque limit #3 Regenerative torque limit #3
Power running torque limit #4 Regenerative torque limit #4
250% torque
250% torque
Power running
Regenerative
Forward
Reverse
Power running
Regenerative
RR-CC 0 10V
RX-CC 0 10V
VI-CC 0 10V
II-CC 4(0) 20mA
,