Toshiba VF-A7 Welding System User Manual


 
F-76
Setting of operation command (RS485)
Title Function Adjustment range Default setting Setting

Operation command
mode selection
 
(Terminal block enabled) (RS485)
Note) To use inter-drive communication (),  can't be set at for master and slave
inverter.
Setting of speed reference (RS485)
Title Function Adjustment range Default setting Setting

Speed setting mode
selection
 
(RR) (RS485)
Note) To use inter-drive communication (),  can't be set at for master inverter.
Communication parameters (standard RS485)
These parameters are used to set or change the data transmission speed, the parity, inverter
numbers and the communication error trip timer with the control panel and or a linked control.
Title Function Adjustment range Default setting
 Parity(common serial/RS485)
: No parity, : Even parity,
: Odd parity
 Inverter number 

Communication time-out
(common serial/RS485)
: OFF,   [s]
RS485 Common serial
No action No action
Alarm No action
Trip No action
No action Alarm
Alarm Alarm
Trip Alarm
No action Trip
Alarm Trip

Communication time-out action
(common serial/RS485)
Trip Trip
 Frequency point selection
: invalid
: Common serial
: RS485
: Communications add-on cassette
option
 Point #1 setting   [%]
 Point #1 frequency   [Hz] 
 Point #2 setting   [%] 
 Point #2 frequency   [Hz] 
 Communication rate (RS485)
: 1200 [bps]
: 2400 [bps]
: 4800 [bps]
: 9600 [bps]
: 19200 [bps]
: 38400 [bps]
 RS485 communication system : 2-line system, 1: 4-line system

RS485 communication waiting
time
: Norm,   [s] 

Inter-drive communication
(RS485)
0: Normal communications
(slave operation)
1: Master (frequency reference)
2: Master (output frequency)
3: Master (torque reference)
4: Master (output torque)
No action: No action is taken even if a timeout occurs.
Alarm: An alarm goes off if a timeout occurs. The message "" blinks at the left end of the
control panel.
Tripping: The inverter trips if a timeout occurs. The message "" blinks on the control panel.
Note) Changes to the parameters , , ,  do not take effect until the power
is turned off and
then on again. When inter-drive communication is used, the parameter 
is set at 0.02 or more.