Toshiba VF-A7 Welding System User Manual


 
J-19
[31] Meter output (2/2)
Vector control
Title
Communi
cation No
Function Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
To rque
control
Position
control
V/f
Constant
Reference
section


0690
0697
AM/FM output parameter for adjustment
[32] Control panel parameters
Vector control
Title
Communi
cation No
Function Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
To rque
control
Position
control
V/f
Constant
Reference
section
 0700
Prohibition of parameter setting
0: Allowed 1: Prohibited 0Enabled/ / / 6.29.1
 0701
Current/voltage display mode
0: [%], 1: [A] or [V] 0Enabled/ / / 6.29.2
 0702
Frequency free unit magnification
0.00: OFF, 0.01 200.0 0.01/0.01 0.00 Enabled / / / 6.29.3
 0703
Decimal place number of frequency
0: 1 [Hz], 1: 0.1 [Hz], 2: 0.01 [Hz] 1Enabled/ / / 6.29.4
 0704
Decimal place number of acc/dec time
0: 1[s], 1: 0.1[s], 2: 0.01[s] 1Enabled/ / / 6.29.4
 0709
Prohibition of user parameter
initialization at type form initialization
0: Allowed
1: Prohibited
0Enabled
 0710 Monitor display mode setting 0 29 0Enabled/ / / 8.1
 0711
Status monitor #1 display mode
0 29 1Enabled/ / / 8.1
 0712
Status monitor #2 display mode
0 29 2Enabled/ / / 8.1
 0713
Status monitor #3 display mode
0 29 3Enabled/ / / 8.1
 0714
Status monitor #4 display mode
0 29 4Enabled/ / / 8.1
 0720
Selection of panel V/f1, 2, 3 or 4
1: V/f #1, 2: V/f #2, 3: V/f #3, 4: V/f #4 1Enabled 6.29.6
 0721 Panel stop pattern 0: Deceleration stop 1: Coast stop 0 Disabled / / / 6.29.7
 0722 Panel reset function 0: Disabled, 1: Enabled 1 Disabled / / / 6.29.8
 0723 Panel torque limit 1 4 1Enabled/ / / 6.29.9
 0724 Panel PID control OFF 0: ON, 1: OFF 0Enabled/ 6.29.10
 0725 Panel torque reference 0 250 [%] 1/0.01 0 Enabled / 6.29.11
 0726
Panel synchronized torque bias
-250 250 [%] 1/0.01 0 Enabled / / 6.21.4
 0727 Panel tension torque bias -250 250 [%] 1/0.01 0 Enabled / 6.21.4
 0728 Panel load sharing gain 0 250 [%] 1/0.01 100 Enabled / 6.21.4
 0729
Panel over-ride multiplication gain
-100 100 [%] 1/0.01 0 Enabled / 6.29.13
 0730 Panel operation prohibition
0: All key operations prohibited
+1: Panel frequency setting enabled
+2: Parameter reading/writing enabled
+4: Monitor display operation enabled
+8: Panel drive operation enabled
(+16: no function)
+32: Emergency stop operation enabled
63: Default mode (all key operation enabled)
63 Disabled / / / 6.29.14
Sensorless vector/vector with sensor ( valid, :invalid)