J-3
2. Extended parameters
[1] Frequency signal
Vector control
Title
Communi
cation No.
Function Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
Torque
control
Position
control
V/f
Constant
Reference
section
0100
Low-speed signal output frequency
0.0 [Hz] 0.01/0.01 0.0 Enabled / / / 6.1.1
0101
Speed reach setting frequency
0.0 [Hz] 0.01/0.01 0.0 Enabled / / / 6.1.2
0102 Speed reach detection band 0.0 [Hz] 0.01/0.01 2.5 Enabled / / / 6.1.2
[2] Input signal selection
Vector control
Title
Communi
cation No
.
Function Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
Torque
control
Position
control
V/f
Constant
Reference
section
0103
ST (standby) signal selection
0: Standard, 1: Always ON, 2: Interlock with F/R terminal
0 Disabled / / / 6.2.1
0105
Priority selection (both F-CC, R-CC are ON)
0: Reverse, 1: Stop 0 Disabled / / / 6.2.2
0106
Priority setting of input terminal
0: Disabled, 1: Enabled 0 Disabled / / / 6.2.3
0107
Binary/BCD signal selection
(Expansion TB option unit)
0: None
1: 12-bit binary input
2: 16-bit binary input
3: 3-digit BCD input
4: 4-digit BCD input
5: Reverse 12-bit binary input
6: Reverse 16-bit binary input
7: Reverse 3-digit BCD input
8: Reverse 4-digit BCD input
0 Disabled / /
0108 Up-down frequency 0 7 1/1 0 Disabled / / /
[3] Terminal function selection (1/2)
Vector control
Title
Communi
cation No.
Function Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
To rque
control
Position
control
V/f
Constant
Reference
section
0110
Always active function selection
0 135 0 Disabled / / / 6.3.1
0111
Input terminal selection #1 (F)
0 135 2(F) Disabled / / / 7.2.1
0112
Input terminal selection #2 (R)
0 135 4(R) Disabled / / / 7.2.1
0113
Input terminal selection #3 (ST)
0 135 6(ST) Disabled / / / 7.2.1
0114
Input terminal selection #4 (RES)
0 135 8(RES) Disabled / / / 7.2.1
0115
Input terminal selection #5 (S1)
0 135 10(S1) Disabled / / / 7.2.1
0116
Input terminal selection #6 (S2)
0 135 12(S2) Disabled / / / 7.2.1
0117
Input terminal selection #7 (S3)
0 135 14(S3) Disabled / / / 7.2.1
0118
Input terminal selection #8 (S4)
0 135 16(S4) Disabled / / / 7.2.1
0119
Input terminal selection #9 (B8)
0 135 0 Disabled / / / 7.2.1
0120
Input terminal selection #10 (B9)
0 135 0 Disabled / / / 7.2.1
(Reference section): Refer to the inverter's individual manual.
Sensorless vector/vector with sensor ( valid, :invalid)