Toshiba VF-A7 Welding System User Manual


 
J-14
[25] Speed/torque reference gain/bias setup #2(2/2)
Vector control
Title
Communi
cation No
Function Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
To rque
control
Position
control
V/f
Constant
Reference
section
 0483
Modulation rate control
margin (voltage control)
80.0 300.0 [%] 0.1/0.01 105.0 Enabled
 0484
Modulation rate control
margin (V/f control)
80.0 300.0 [%] 0.1/0.01 105.0 Enabled
 0485
Stall cooperation gain at field
weakening zone
0 255 1/1 128 Enabled
 0486 Exciting starting rate 1.64 327.6 0.01/0.01 163.8 Enabled
 0487
Compensation coefficient for iron loss
0 255 1/1 10 Enabled
 0488
Voltage compensation
coefficient for dead time
0.00 327.6 0.01/0.01 See J-28 Enabled
 0489 Dead time compensation 0: Enabled, 1: Disabled 0Enabled
 0490
Dead time compensation (bias time)
-32.7 32.7 0.01/0.001 0.00 Enabled
 0491
Current / voltage control
switching frequency
10.0 60.0 [Hz] 0.1/0.01 40.0 Enabled
[26] Secondary acceleration/deceleration
Vector control
Title
Communi
cation No
Function Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
To rque
control
Position
control
V/f
Constant
Reference
section
 0500 Acceleration time #2 0.1() 6000 [s] 0.01/0.01* See J-28 Enabled / 6.23.2
 0501 Deceleration time #2 0.1() 6000 [s] 0.01/0.01* See J-28 Enabled / 6.23.2
 0502
Acceleration/deceleration pattern #1
0: Linear, 1: S-pattern #1, 2: S-pattern #2 0Enabled/ 6.23.1
 0503
Acceleration/deceleration pattern #2
0: Linear, 1: S-pattern #1, 2: S-pattern #2 0Enabled/ 6.23.2
 0504
Acceleration/deceleration
#1,2,3,4 selection
1: Acceleration/deceleration #1
2: Acceleration/deceleration #2
3: Acceleration/deceleration #3
4: Acceleration/deceleration #4
1Enabled/ 6.23.2
 0505
Acc/dec switching frequency #1
0.0  [Hz] 0.01/0.01 0.0 Enabled / 6.23.2
 0506
S-pattern lower-limit adjustment amount
0 50 [%] 1/0.01 25 Enabled /
 0507
S-pattern upper-limit adjustment amount
0 50 [%] 1/0.01 25 Enabled /
6.23.1
 0508 Acc/dec time lower limit 0.01 10.00 [s] 0.01/0.01* 0.10 Enabled / 6.23.3
 0510 Acceleration time #3 0.1() 6000 [s] 0.01/0.01* See J-28 Enabled / 6.23.2
 0511 Deceleration time #3 0.1() 6000 [s] 0.01/0.01* See J-28 Enabled / 6.23.2
 0512
Acceleration/deceleration pattern #3
0: Linear, 1: S-pattern #1, 2: S-pattern #2 0Enabled/ 6.23.2
 0513
Acc/dec switching frequency #2
0.0  [Hz] 0.01/0.01 0.0 Enabled / 6.23.2
 0514 Acceleration time #4 0.1() 6000 [s] 0.01/0.01* See J-28 Enabled / 6.23.2
 0515 Deceleration time #4 0.1() 6000 [s] 0.01/0.01* See J-28 Enabled / 6.23.2
 0516
Acceleration/deceleration pattern #4
0: Linear, 1: S-pattern #1, 2: S-pattern #2 0Enabled/ 6.23.2
 0517
Acc/dec switching frequency #3
0.0  [Hz] 0.01/0.01 0.0 Enabled / 6.23.2
(Reference section): Refer to the inverter's individual manual.
* Minimum setup unit is 0.1 in case of 16-bit access. Sensorless vector/vector with sensor ( :valid, :invalid)