I-9
Selection table of separate-type options
Radio noise reduction filter
Volta
g
e
class
A
pplicable
motor
[kW]
Inverter
model
Input AC
reactor
(
ACL
)
DC reactor
(DCL)
High
attenuation
type
Simple
t
y
pe
Core
t
y
pe
(
*1
)
Brakin
g
resistor
(*2, 3, 4)
Motor end
sur
g
e volta
g
e
suppression
filter
Motor
noise
reduction
filter
0.4
VFA7-2004PL
0.75
VFA7-2007PL
PFL-2005S
DCL-2007
(*9)
1.5
VFA7-2015PL
2.2
VFA7-2022PL
PFL-2011S DCL-2022
3.7
VFA7-2037PL PFL-2018S DCL-2037
5.5
VFA7-2055PL PFL-2025S DCL-2055 PBR3-2055
7.5
VFA7-2075PL PBR3-2075
11
VFA7-2110P
PFL-2050S DCL-2110
NF-3050A-MJ PBR3-2110
15
VFA7-2150P
18.5
VFA7-2185P
NF-3080A-MJ PBR3-2150
22
VFA7-2220P
PFL-2100S DCL-2220
NF-3100A-MJ
30
VFA7-2300P
PBR3-2220
37
VFA7-2370P1
PFL-2150S DCL-2370 NF-3150A-MJ
45
VFA7-2450P1 PFL-2200S DCL-2450 NF-3200A-MJ
RC9129
55
VFA7-2550P1 PFL-2300S DCL-2550 NF-3250A-MJ
PBR-222W002
NRL-2220
75
VFA7-2750P1 PFL-2400S DCL-2750
NF-3200A-MJ
2 (parallel)
NRL-2300
200V
class
90
VFA7-2900P1 PFL-2600S DCL-2900
NF-3250A-MJ
2 (parallel)
RCL-M2
RC9129
(*5)
DGP600W-B1
[DGP600W-C1]
NRL-2400
0.75
VFA7-4007PL
1.5
VFA7-4015PL
DCL-2007
(*7)
(*9)
MSF-4015Z
2.2
VFA7-4022PL
3.7
VFA7-4037PL
PFL-4012S
DCL-2022
(*7)
MSF-4037Z
5.5
VFA7-4055PL PBR3-4055
7.5
VFA7-4075PL PBR3-4075
MSF-4075Z
11
VFA7-4110PL
PFL-4025S DCL-4110
PBR3-4110
15
VFA7-4150PL
MSF-4150Z
18.5
VFA7-4185P NF-3040C-MJ
PBR3-4150
22
VFA7-4220P
PFL-4050S DCL-4220
NF-3050C-MJ
MSF-4220Z
30
VFA7-4300P NF-3060C-MJ
PBR3-4220
37
VFA7-4370P1 NF-3080C-MJ
MSF-4370Z
45
VFA7-4450P1
PFL-4100S DCL-4450
NF-3100C-MJ
55
VFA7-4550P1
RC9129
MSF-4550Z
75
VFA7-4750P1
PFL-4150S DCL-4750 NF-3150C-MJ
PBR-417W008
MSF-4750Z NRL-4155
90/110
VFA7-4110KP1 PFL-4300S DCL-4110K NF-3250C-MJ NRL-4230
132
VFA7-4132KP1
NF-3200C-MJ
2 (parallel)
NRL-4300
160
VFA7-4160KP1
PFL-4400S DCL-4160K
NF-3200C-MJ
2 (parallel)
DGP600W-B2
[DGP600W-C2]
NRL-4350
220
VFA7-4220KP1 PFL-4600S DCL-4220K
NF-3250C-MJ
2 (parallel)
DGP600W-B3
[DGP600W-C3]
NRL-4600
400V
class
280
VFA7-4280KP1 PFL-4800S DCL-4280K
NF-3250C-MJ
3 (parallel)
RCL-M4
RC9129
(*5)
DGP600W-B4
[DGP600W-C4]
(*6)
NRL-4550
(*1): This filter needs to be wound 4 turns or more around with the input side power line. This filter can
be used for the output side in the same manner. For the wire whose size is 22 mm
2
or more, install
at least 4 filters in series. Round type (Model: RC5078) is also available.
(*2): PBR3- indicates braking resistor.
(*3): Model in square brackets is fitted with top cover.
(*4): To use 200 V-75 kW or more or 400 V-110 kW or more inverter with an external braking resistor
(DGP600 series), installation of a dynamic braking drive circuit inside the inverter is required.
(*5): There is a case that this filter is unusable depending on the type or size of the cable to be used.
(*6): About this filter for inverter models of 90 kW or more, consult with our office
(*7): These reactors are usable for each of 200V class and 400V class.
(*8): Be sure to connect DC reactor to 200V-75kW or more or 400V-110kW or more inverter. (Not
necessary for DC input.)
(*9): When connecting DCL-2007 to VFA7-2004PL, 2007PL, 4007PL and 4015PL, the terminal of
DCL-2007 is processed so that the screw size of inverter’s main circuit terminal may be suited.