J-6
[7] Speed/torque reference gain/bias setup (1/2)
Vector control
Title
Communi
cation No
Function Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
To rque
control
Position
control
V/f
Constant
Reference
section
 0200 Reference priority selection
0: 
1: 
2:  priority (*1)
3:  priority (*2)
4: / switching
0Enabled/ 6.6.1
 0201 VI/II reference point #1 0 100 [%] 1/0.01 20.0 Enabled / / 7.3.2
 0202
VI/II reference point #1 frequency
0.0  [Hz] 0.01/0.01 0. 0 Enabled / / 7.3.2
 0203 VI/II reference point #2 0 100 [%] 1/0.01 100 Enabled / / 7.3.2
 0204
VI/II reference point #2 frequency
0.0  [Hz] 0.01/0.01 80.0 Enabled / 7.3.2
 0205 VI/II reference point #1 rate -250 250 [%] (For torque control, etc.) 1/0.01 0 Enabled / / 6.21.1
 0206 VI/II reference point #2 rate -250 250 [%] (For torque control, etc.) 1/0.01 100 Enabled / / 6.21.1
 0207
Speed setting mode selection #2
Same as  (1 to 11) 1Enabled/ 6.61
 0208

/

switching frequency
0.1  [Hz] 0.01/0.01 1.0 Enabled / 6.6.1
 0209 Analog input filter 0(Disabled) to 3(Max. filter capacity) 0Enabled/ / 7.2.4
 0210 RR reference point #1 0 100 [%] 1/0.01 0 Enabled / / 7.3.1
 0211
RR reference point #1 frequency
0.0  [Hz] 0.01/0.01 0.0 Enabled / 7.3.1
 0212 RR reference point #2 0 100 [%] 1/0.01 100 Enabled / / 7.3.1
 0213
RR reference point #2 frequency
0.0  [Hz] 0.01/0.01 80.0 Enabled / 7.3.1
 0214 RR reference point #1 rate 0 250 [%] (For torque control, etc.) 1/0.01 0 Enabled / / 6.21.1
 0215 RR reference point #2 rate 0 250 [%] (For torque control, etc.) 1/0.01 100 Enabled / / 6.21.1
 0216 RX reference point #1 -100 100 [%] 1/0.01 0 Enabled / / 7.3.3
 0217
RX reference point #1 frequency
-  [Hz] (*3) 0.01/0.01 0.0 Enabled / 7.3.3
 0218 RX reference point #2 -100 100 [%] 1/0.01 100 Enabled / / 7.3.3
 0219
RX reference point #2 frequency
-  [Hz] (*3) 0.01/0.01 80.0 Enabled / 7.3.3
 0220 RX reference point #1 rate 0 250 [%] (For torque control, etc.) 1/0.01 0 Enabled / / 6.21.1
 0221 RX reference point #2 rate 0 250 [%] (For torque control, etc.) 1/0.01 100 Enabled / / 6.21.1
 0222 RX2 reference point #1 -100 100 [%] 1/0.01 0 Enabled / /
 0223
RX2 reference point #1 frequency
-  [Hz] (*3) 0.01/0.01 0.0 Enabled /
 0224 RX2 reference point #2 -100 100 [%] 1/0.01 100 Enabled / /
 0225
RX2 reference point #2 frequency
-  [Hz] (*3) 0.01/0.01 80.0 Enabled /
 0226 RX2 reference point #1 rate -250 250 [%] (For torque control, etc.) 1/0.01 0 Enabled / /
 0227 RX2 reference point #2 rate -250 250 [%] (For torque control, etc.) 1/0.01 100 Enabled / /
(*1): When setup frequency(signal set up by ) is  or more, signal set up by  is accepted, When setup frequency is lower than , the inverter runs under the signal of .
(*2): When setup frequency(signal set up by ) is  or more, signal set up by  is accepted, When setup frequency is lower than , the inverter runs under the signal of .
(*3): Adjustment range is -327.68 327.67 [Hz] in case of 16-bit access.
(Reference section): Refer to the inverter's individual manual.
Sensorless vector/vector with sensor ( valid, :invalid)