Toshiba VF-A7 Welding System User Manual


 
J-11
[20] Vector control
Vector control
Title
Communi
cation No
Function Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
To rque
control
Position
control
V/f
Constant
Reference
section
 0374
Current control proportional gain
1.0 1000 0.1/0.1 209.1 Disabled / / /
 0375 Current control integral gain 1.0 1250 0.1/0.1 See J-28 Disabled / / /
 0376 Speed loop proportional gain 3.2 1000 0.1/0.1 See J-28 Enabled / /
 0377 Speed loop integral gain 0.1 200. 0 [rad/s] 0.1/0.1 See J-28 Enabled / /
 0378 Motor counter data selection 0 5 0 Disabled / /
 0379 Speed loop parameter ratio 0.01 10.00 [s] 0.01/0.01 1.00 Disabled / /
[21] Preset-speed operation mode
Vector control
Title
Communi
cation No
Function Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
To rque
control
Position
control
V/f
Constant
Reference
section
 0380
Preset-speed operation
mode
0: Non-mode preset speed
1: Preset speed by mode
0 Disabled / 5.14
 0381
Preset-speed #1 control mode
0: Forward run
+1: Reverse run
+2: Selection of acc/dec switching #1
+4: Selection of acc/dec switching #2
+8: Selection of V/f switching #1
+16: Selection of V/f switching #2
+32: Selection of torque limit switching #1
+64: Selection of torque limit switching #2
0 Disabled / 5.14
 0382
Preset-speed #2 control mode
Ditto 0 Disabled / 5.14
 0383
Preset-speed #3 control mode
Ditto 0 Disabled / 5.14
 0384
Preset-speed #4 control mode
Ditto 0 Disabled / 5.14
 0385
Preset-speed #5 control mode
Ditto 0 Disabled / 5.14
 0386
Preset-speed #6 control mode
Ditto 0 Disabled / 5.14
 0387
Preset-speed #7 control mode
Ditto 0 Disabled / 5.14
 0388
Preset-speed #8 control mode
Ditto 0 Disabled / 5.14
 0389
Preset-speed #9 control mode
Ditto 0 Disabled / 5.14
 0390
Preset-speed #10 control mode
Ditto 0 Disabled / 5.14
 0391
Preset-speed #11control mode
Ditto 0 Disabled / 5.14
 0392
Preset-speed #12 control mode
Ditto 0 Disabled / 5.14
 0393
Preset-speed #13 control mode
Ditto 0 Disabled / 5.14
 0394
Preset-speed #14 control mode
Ditto 0 Disabled / 5.14
 0395
Preset-speed #15 control mode
Ditto 0 Disabled / 5.14
 0396 Torque reference filter #2 10.0 199.9, 200.0(No filters) 1/0.1 200.0 Enabled / / 6.21.2
 0397 Speed loop proportional gain #2 3.2 1000 0.1/0.1 See J-28 Enabled / /
 0398 Speed loop integral gain #2 10.0 200. 0 [rad/s] 0.1/0.1 See J-28 Enabled / /
(Reference section): Refer to the inverter's individual manual.
Sensorless vector/vector with sensor ( valid, :invalid)