E-15
5.6 Forward/reverse run selection (for the panel control only)
Forward/reverse selection
Parameter setting
Title Function Adjustment range Default setting
Forward/reverse selection
: Forward run
: Reverse run
The direction of rotation can be checked in status monitor mode.
: Forward run, : Reverse run => Refer to 8.1
When the terminal board is used for operation, the direction of rotation is switched with the
terminal F,R. Consequently, the forward/reverse run selection parameter becomes invalid.
F-CC connected: Forward run
R-CC connected: Reverse run
If F and CC, as well as R and CC are connected at the same time: Reverse run (Default setting)
Use the parameter to change the direction of rotation in this case.
=> Refer to 6.2.2 for details.
This parameter is valid only when is set at (Operating panel enabled.)
5.7 Maximum frequency
Maximum frequency
When increasing the , adjust the upper limit frequency parameter as well, if necessary.
[Parameter setting]
Title Function Adjustment range Default setting
Maximum frequency
[Hz]
Function
This parameter is used to set the direction of a motor when it is started or stopped by pressing the
Run key or Stop key on the control panel. This parameter is valid only when the operation command
mode selection parameter is set at (control panel input enabled).
Function
1) This parameter is used to set the range of frequencies (the maximum frequency) that the
inverter can output.
2) The frequency is used a the reference for setting the acceleration and deceleration times.
Output freq. [Hz]
: In case of =80Hz
: In case of =60Hz
80
60
0 100
Frequency setting signal [%]
Set the maximum frequency
according to the rating of the
motor.
The maximum frequency cannot
be adjusted during operation. So,
put the inverter out of operation
when making this setting.