Toshiba VF-A7 Welding System User Manual


 
G-9
7. 2. 3 Setup of input/output terminal operation time
Setup of response time
Title Function Adjustment range Default value

Input terminal #1 response time (F)
  [ms]

Input terminal #2 response time (R)
  [ms]

Input terminal #3 response time (ST)
  [ms]

Input terminal #4 response time (RES)
  [ms]

Input terminal #5 8 response time
  [ms]

Input terminal #9 16 response time
  [ms]

Output terminal #1 delay time (OUT1)
  [ms]

Output terminal #2 delay time (OUT2)
  [ms]

Output terminal #3 delay time (FL)
  [ms]

Output terminal #4 delay time
  [ms]

Output terminal #5 delay time
  [ms]

Output terminal #6 delay time
  [ms]

Output terminal #7 delay time
  [ms]

Output terminal #1 holding time (OUT1)   [ms]

Output terminal #2 holding time (OUT2)   [ms]

Output terminal #3 holding time (FL)   [ms]

Output terminal #4 holding time   [ms]

Output terminal #5 holding time   [ms]

Output terminal #6 holding time   [ms]

Output terminal #7 holding time   [ms]
Setting when vector option unit or expansion TB option unit is used.
Note): The minimum setting unit is 1 ms, but that of response time is 2.5 ms. Input the value which omitted
below the decimal point of a multiple of 2.5.
7. 2. 4 Analog input filter
Response time setting
Title Function Adjustment range Default value

Analog input filter (Disabled) to (maximum filter capacity)
Function
The input/output terminal operation time setup function is used to extend response time if
there is something malfunctioning because of noise or chattering of input relay.
For each output terminal, delay time at turning on or off can be set individually.
Function
This function is effective to remove noise from the frequency setting circuit. If operation is unstable
because of noise, increase the time constant of the analog input filter.