Toshiba VF-A7 Welding System User Manual


 
H-5
Setup values of monitor indication parameters( )
Com.
No.
Setup
value
Function Indication Unit(Panel)
Unit(Com-
munication)
FD00 0
Running frequency

Depends
on 
0.01[Hz]
FE02 1 Frequency command

ditto 0.01[Hz]
FE03 2 Current

1[%] or

0.01[%]
FE04 3 DC voltage

ditto 0.01[%]
FE05 4 Output voltage

ditto 0.01[%]
FE015 5 After-compensation frequency

Depends
on 
0.01[Hz]
FE16 6 Speed feedback (real-time value)
ditto 0.01[Hz]
FE17 7 Speed feedback (1 second filter)
ditto 0.01[Hz]
FE18 8 Torque

1[%] 0.01[%]
FE19 9 Torque reference

1[%] 0.01[%]
FE56 10 Internal torque reference (*1)

1[%] 0.01[%]
FE20 11 Torque current

1[%] 0.01[%]
FE21 12 Exciting current

1[%] 0.01[%]
FE22 13 PID feedback value

Depends
on 
0.01[Hz]
FE23 14 Motor overload factor (OL2 data)

1[%] 0.01[%]
FE24 15 Inverter overload factor (OL1 data)

1[%] 0.01[%]
FE25 16 PBr overload factor (PBrOL data)

1[%] 0.01[%]
FE28 17 PBr load factor (pulse duty)

1[%] 0.01[%]
FE29 18 Input power

0.1[kW] 0.01[kW]
FE30 19 Output power

0.1[kW] 0.01[kW]
FE31 20 Peak output current

1[%] or

0.01[%]
FE32 21 Peak DC voltage

ditto 0.01[%]
FE33 22 Motor counter dummy PG

1/100 count 1 count
FE34 23 Position pulse

1/100 count 1 count
FE35 24 PR input

1[%] 0.01[%]
FE36 25 VI/II input

1[%] 0.01[%]
GE37 26 RX input

1[%] 0.01[%]
FE38 27 RX2 input

1[%] 0.01[%]
FE39 28 FM output

1[%] 0.01[%]
FE40 29 AM output

1[%] 0.01[%]