Toshiba VF-A7 Welding System User Manual


 
J-18
[29] Special analog input
Vector control
Title
Communi
cation No
Function Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
To rque
control
Position
control
V/f
Constant
Reference
section
 0650
Acceleration/deceleration
base frequency adjustment
0: Invalid 1: VI/II 2: RR 0Enabled/ 6.26
 0651
Upper-limit frequency adjustment
0: Invalid 1: VI/II 2: RR 0Enabled/ 6.26
 0652 Acceleration time adjustment 0: Invalid 1: VI/II 2: RR 0Enabled/ 6.26
 0653
Deceleration time adjustment
0: Invalid 1: VI/II 2: RR 0Enabled/ 6.26
 0654
Manual torque boost adjustment
0: Invalid 1: VI/II 2: RR 0Enabled 6.26
[30] Over-ride
Vector control
Title
Communi
cation No
Function Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
To rque
control
Position
control
V/f
Constant
Reference
section
 0660
Over-ride addition input
selection
0: Disabled
1: VI (voltage input)/II (current input)
2: RR (volume/voltage input)
3: RX (voltage input)
4: RX2 (voltage input) (optional)
5: Operating panel input
6: Binary/BCD input
7: Common serial communication option(FA01)
8: Serial communication RS485(FA05)
9: Communication add-on cassette option(FA07)
10: Up-down frequency
11: Pulse input #1 (optional)
0Enabled/ 6.27
 0661
Over-ride multiplication input selection
0: Disabled,1: VI/II,2: RR,3: RX,4: RX2,5:  0Enabled/ 6.27
[31] Meter output (1/2)
Vector control
Title
Communi
cation No
Function Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
To rque
control
Position
control
V/f
Constant
Reference
section
 0670 AM terminal meter selection 0 32
2(output
current)
Enabled / / / 5.4
 0671 AM terminal meter adjustment Enabled / / / 5.4
 0672
Optional analog terminal #1 meter selection
0 32 4Enabled/ / /
 0673
Optional analog terminal #1 meter adjustment
Enabled / / /
 0674
Optional analog terminal #2 meter selection
0 32 5Enabled/ / /
 0675
Optional analog terminal #2 meter adjustment
Enabled / / /
 0676 FP terminal meter selection 0 32 0Enabled/ / / 6.28.3
 0677 FP terminal meter adjustment 1.00 43.20 0.01/0.001 3.84 Enabled / / / 6.28.3
 0678 Optional analog terminal #1 meter offset -10.0 60.0 0.1/0.1 0.0 Enabled / / /
 0679 Optional analog terminal #2 meter offset -10.0 60.0 0.1/0.1 0.0 Enabled / / /
 0680 Optional analog terminal sign selection 0 3 0Enabled/ / /
(Reference section): Refer to the inverter's individual manual.
Sensorless vector/vector with sensor ( valid, :invalid)