Mitsubishi Electronics FR-E700EX Welder User Manual


 
117
Speed setting by external terminals
4
PARAMETERS
4.8 Speed setting by external terminals
4.8.1 Operation by multi-speed operation (Pr.4 to Pr.6, Pr.24 to Pr.27, Pr.232 to Pr.239)
The above parameters allow its setting to be changed during operation in any operation mode even if "0" (initial value) is set in Pr.77 Parameter write selection.
 This parameter can be set when Pr.160 Extended function display selection = "0". (Refer to page 182)
 When a value exceeding 3000 r/min is set, the rotation speed will be limited at 3000 r/min.
Also, when an S-PM geared motor is used, the maximum setting value differs depending on the drive unit capacity. (0.2 to 2.2K: 12000 r/min, 3.7K: 8000 r/
min)
Purpose Parameter to set Refer to page
To make speed setting by
combination of terminals
Multi-speed operation
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
117
To perform Jog operation Jog operation Pr.15, Pr.16
119
To command smooth speed
transition with terminals
Remote setting function Pr.59
122
Can be used to change the preset speed in the parameter with the contact signals.
Any speed can be selected by merely turning ON/OFF the contact signals (RH, RM, RL, REX signals).
Parameter
number
Name
Initial
value
Setting range Description
4
Multi-speed setting (high
speed)
3000r/min 0 to 4800r/min Speed when RH turns ON
5
Multi-speed setting (middle
speed)
1500r/min 0 to 4800r/min Speed when RM turns ON
6 Multi-speed setting (low speed)
300r/min 0 to 4800r/min Speed when RL turns ON
24 Multi-speed setting (speed 4)
9999 0 to 4800r/min, 9999
Speed from 4 speed to 15 speed can be
set according to the combination of the
RH, RM, RL and REX signals.
9999: not selected
25 Multi-speed setting (speed 5)
9999 0 to 4800r/min, 9999
26 Multi-speed setting (speed 6)
9999 0 to 4800r/min, 9999
27 Multi-speed setting (speed 7)
9999 0 to 4800r/min, 9999
232 Multi-speed setting (speed 8)
9999 0 to 4800r/min, 9999
233 Multi-speed setting (speed 9)
9999 0 to 4800r/min, 9999
234 Multi-speed setting (speed 10)
9999 0 to 4800r/min, 9999
235 Multi-speed setting (speed 11)
9999 0 to 4800r/min, 9999
236 Multi-speed setting (speed 12)
9999 0 to 4800r/min, 9999
237 Multi-speed setting (speed 13)
9999 0 to 4800r/min, 9999
238 Multi-speed setting (speed 14)
9999 0 to 4800r/min, 9999
239 Multi-speed setting (speed 15)
9999 0 to 4800r/min, 9999
(1) Multi-speed setting for 3 speeds (Pr.4 to Pr.6)
The drive unit operates at speeds set in Pr.4 when RH signal is ON,
Pr.5 when RM signal is ON and Pr.6 when RL signal is ON.
REMARKS
In the initial setting, if two or three of multi-speed settings are simultaneously selected, priority is given to the set speed of the
lower signal.
For example, when the RH and RM signals turn ON, the RM signal (Pr.5) has a higher priority.
The RH, RM, RL signals are assigned to the terminal RH, RM, RL in the initial setting. By setting "0 (RL)", "1 (RM)", "2 (RH)" in
any of Pr.178 to Pr.184 (input terminal function selection), you can assign the signals to other terminals.
Speed 1
(High speed)
Speed 2
(Middle speed)
Speed 3
(Low speed)
ON
ON
ON
RL
RH
RM
Rotation speed (r/min)
Time