Mitsubishi Electronics FR-E700EX Welder User Manual


 
Parameter listParameter list
58
P
a
r
a
m
e
t
e
r
L
i
s
t
4
PARAMETERS
Life diagnosis
255 Life alarm status display (0 to 15) 1 0 245 255 3F BF 2
256 Inrush current limit circuit life display (0 to 100%) 1% 100% 245 256 40 C0 2 
257 Control circuit capacitor life display (0 to 100%) 1% 100% 245 257 41 C1 2
258 Main circuit capacitor life display (0 to 100%) 1% 100% 245 258 42 C2 2 
259 Main circuit capacitor life measuring 0,1 (2, 3, 8, 9) 1 0 245 259 43 C3 2
267 Terminal 4 input selection 0, 1, 2 1 0 168 267 4B CB 2 
268 Monitor decimal digits selection 0, 1, 9999 1 9999 155 268 4C CC 2
269 Parameter for manufacturer setting. Do not set. 269 Parameter for manufacturer setting. Do not set.
285
Excessive speed deviation detectiond
speed
0 to 360r/min, 9999 1r/min 9999 84 285 5D DD 2
295 Magnitude of speed change setting 0, 0.01, 0.1, 1, 10 0.01 0 259 295 67 E7 2 
Password
function
296 Password lock level 0 to 6, 100 to 106, 9999 1 9999 183 296 68 E8 2
297 Password lock/unlock
(0 to 5), 1000 to 9998, 9999
1 9999 183 297 69 E9 2 
Digital input
313
DO0 output selection
0, 1, 3, 4, 7, 8, 11 to 16, 21,
24, 26, 33, 36, 38, 47, 55,
56, 60, 61, 63, 64,90, 91, 93,
95, 96, 98, 99, 100, 101,
103, 104, 107, 108,
111 to 116, 121, 124, 126,
133, 136, 138, 147, 155,
156, 160, 161, 163, 164,
190, 191, 193, 195, 196,
198, 199, 9999
1 9999 313 0D 8D 3
314 DO1 output selection 1 9999 314 0E 8E 3 
315 DO2 output selection 1 9999 315 0F 8F 3
RS-485
communication
338
Communication operation command
source
0, 1 1 0 195 338 26 A6 3  
339 Communication speed command source 0, 1, 2 1 0 195 339 27 A7 3  
340  Communication startup mode selection 0, 1, 10 1 0 194 340 28 A8 3  
342 Communication EEPROM write selection 0, 1 1 0 208 342 2A AA 3
343 Communication error count 10222 343 2B AB 3 
349 Communication reset selection 0,1 1 0 349 31 B1 3
374 Overspeed detection level 0 to 4800r/min  1r/min 3450r/min 167 374 4A CA 3 
375 Faulty acceleration rate detection level 0 to 4800r/min , 9999 1r/min/ms 9999 125 375 4B CB 3
Function
Parameter Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter Remarks
Instruction Code
Motor/Control Mode Support Table
Parameter
S-PM MM-GKR
Read Write
Extended
Speed Speed position Copy Clear All clear