PARAMETERS
[Fault data]
Refer to page 267 for details of fault description
[Run command]
 The signal is the default setting. The description changes depending on the setting of Pr.180 to Pr.184 (input terminal function selection) (page 138).
 The signal is the default setting. Reset cannot be controlled by the network, bit 11 is invalid in the initial status. When using bit 11, change the signal with
Pr.184 RES terminal function selection (page 138) (Reset can be executed with the instruction code HFD)
 When Pr.551 = "2" (PU Mode command source is PU connector), only forward rotation and reverse rotation can be used.
Item
Instruction
Code
Bit
Length
Description Example
Run
command
HFA 8 bits
b0: Current input selection (Fixed)
b1: Forward rotation command
(Fixed)
b2: Reverse rotation command
(Fixed)
b3: RL (low speed operation
command) (Variable))
b4: RM (middle speed operation
command (Variable))
b5: RH (high speed operation
command (Variable))
b6: Second function selection
(Fixed)
b7: MRS (output stop
(Variable))
Run
command
(expansion)

HF9 16 bits
b0: Current input selection (Fixed)
b1: Forward rotation command
(Fixed)
b2: Reverse rotation command
(Fixed)
b3: RL (low speed operation
command (Variable))
b4: RM (middle speed operation
command (Variable))
b5: RH (high speed operation
command (Variable))
b6: Second function selection
(Fixed)
b7: MRS (output stop
(Variable))
b8:
b9:
b10:
b11:
RES (Reset (Variable))

b12:
b13:
b14:
b15:
For read data H3010
(Previous fault... THT)
(Latest fault... OC1)
0
1
0
1
0000 0 1 0000
00
b15 b8b7 b0
Latest fault
(HA1)
Previous fault
(H30)
Fault record display example (instruction code H74)
Data Definition
H00
No fault
present
H10 E.OC1
H11 E.OC2
H12 E.OC3
H20 E.OV1
H21 E.OV2
H22 E.OV3
H30 E.THT
H31 E.THM
H40 E.FIN
H52 E.ILF
H60 E.OLT
H61 E.SOT
H70 E.BE
H80 E.GF
H81 E.LF
H90 E.OHT
HA0 E.OPT
HA1 E.OP1
HB0 E.PE
HB1 E.PUE
HB2 E.RET
HB3 E.PE2
HC0 E.CPU
HC5 E.IOH
Data Definition
HC7 E.AIE
HC8 E.USB
HC9 E.SAF
HD0 E.OS
HD1 E.OSD
HD3 E.OD
HDD E.OA
HF1 E.1
HF5 E.5
HF6 E.6
HF7 E.7
HFD E.13
Data Definition
00000010
b7 b0
[Example 1] H02... Forward rotation
[Example 2] H00... Stop
00000000
b7 b0
00000010
b0
[Example 1] H0002... Forward rotation
00000000
b15
00000000
b0
[Example 2] H0800... Low speed operation
(When Pr. 184 RES terminal function selection is set to "0")
00001000
b15