(2) Using the setting dial like a potentiometer to set the speed
Operation example Changing the speed from 0r/min to 1800r/min during operation
Operation Display
1. Screen at power-ON
The monitor display appears.
2. Press to choose the PU operation mode.
PU indicator is ON.
3. Press to choose the parameter setting mode.
PRM indicator is ON.
(The parameter number read previously appears.)
4. Turn until (Pr.161) appears.
5. Press to read the currently set value.
" "(initial value) appears.
6. Turn to change it to the set value " ".
7. Press to set.
Flicker... Parameter setting complete!!
8. Mode/monitor check
Press twice to choose the monitor/speed
monitor.
9. Press to start the drive unit.
10.Turn until " " appears.
The flickering speed is the set speed.
You need not press .
The frequency flickers for about 5s.
REMARKS
If the display changes from flickering "1800" to "0", the setting of Pr.161 Speed setting/key lock operation selection may not be "1".
Independently of whether the drive unit is running or at a stop, the speed can be set by merely turning the dial.
When the speed is changed, it will be stored in EEPROM as the set speed after 10s.