Mitsubishi Electronics FR-E700EX Welder User Manual


 
185
Misoperation prevention and parameter setting restriction
4
PARAMETERS
(3) Parameter operation during password lock/unlock
Parameter operation
Unlocked
Password
registered
Locked
Pr.296 = 9999
Pr.297 = 9999
Pr.296 9999
Pr.297 = 9999
Pr.296 9999
Pr.297 = 0 to 4
(Read value)
Pr.296 = 100 to 106
Pr.297 = 5
(Read value)
Pr.296
Read  
Write  
Pr.297
Read  
Write  
Performing parameter clear   
Performing parameter all clear  
Performing parameter copy 
: enabled, : restricted
 Reading/writing is unavailable when there is restriction to reading by the Pr.160 setting. (Reading is available in NET mode regardless of Pr.160
setting.)
 Unavailable during the operation.
 Correct password will not unlock the restriction.
 Parameter clear is available only from the communication parameter.
REMARKS
When Pr.296 = any of "4, 5, 104, 105" (password lock), the setting screen for PU JOG speed is not displayed in the parameter
unit (FR-PU07).
During password lock, parameter copy of the parameter unit (FR-PU07) cannot be performed.
Parameters referred to
Pr.77 Parameter write selection Refer to page 181
Pr.160 Extended function display selection Refer to page 182
Pr.550 NET mode operation command source selection Refer to page 195
Pr.551 PU mode operation command source selection Refer to page 195