PARAMETERS
Stopper control
512 Stopper control function selection 0, 1, 10, 11, 12 1 0 102 512 0C 8C 5 
513 Stopper control torque limit 0 to 200% 1% 40% 102 513 0D 8D 5
514
Stopper control switchover position lower 4
digits
0 to 9999 1 0 102 514 0E 8E 5 
515
Stopper control switchover position upper
4 digits
0 to 9999 1 0 102 515 0F 8F 5
Position control
525 First positioning sub-function
0, 1, 10, 11, 100, 101,
110, 111
11095 525 19 99 5 
526 Second positioning sub-function
0, 1, 10, 11, 100, 101,
110, 111
1 10 95 526 1A 9A 5
527 Third positioning sub-function
0, 1, 10, 11, 100, 101,
110, 111
11095 527 1B 9B 5 
528 Fourth positioning sub-function
0, 1, 10, 11, 100, 101,
110, 111
1 10 95 528 1C 9C 5
529 Fifth positioning sub-function
0, 1, 10, 11, 100, 101,
110, 111
11095 529 1D 9D 5 
530 Sixth positioning sub-function
0, 1, 10, 11, 100, 101,
110, 111
1 10 95 530 1E 9E 5
531 Seventh positioning sub-function 0, 10, 100, 110 1 10 95 531 1F 9F 5 
532 Home position return selection 2, 3, 4, 6 1 4 104 532 20 A0 5
533 Home position return stopper torque 0 to 200% 0.1% 40% 104 533 21 A1 5 
534 Home position return stopper duration 0 to 10s 0.1s 0.5s 104 534 22 A2 5
535 Position control terminal input selection
0, 1, 10, 11, 100, 101,
110, 111
10100 535 23 A3 5 
536 Position detection selection 0, 1, 2 1 0 109 536 24 A4 5
537 Roll feed mode selection 0, 1 1 0 95 537 25 A5 5 
CC-Link
541
Frequency command sign selection (CC-
Link)
0, 1 1 0 541 29 A9 5
542 Communication station number (CC-Link) 1 to 64 1 1 542 2A AA 5 
543 Baud rate selection (CC-Link) 0 to 4 1 0 543 2B AB 5
544 CC-Link extended setting 0, 1, 12, 14, 18 1 0 544 2C AC 5 
USB
547 USB communication station number 0 to 31 1 0 547 2F AF 5  
548 USB communication check time interval 0 to 999.8s, 9999 0.1s 9999 548 30 B0 5  
Communication
549 Protocol selection 0, 1 1 0
204,
222
549 31 B1 5  
550
NET mode operation command source
selection
0, 2, 9999 1 9999 195 550 32 B2 5 
 
551
PU mode operation command source
selection
2 to 4, 9999 1 9999 195 551 33 B3 5  
Current average
time monitor
555 Current average time 0.1 to 1.0s 0.1s 1s 249 555 37 B7 5 
556 Data output mask time 0 to 20s 0.1s 0s 249 556 38 B8 5
557
Current average value monitor signal
output reference current
0 to 500A 0.01A
Rated
motor
current

249 557 39 B9 5 
563 Energization time carrying-over times (0 to 65535) 1 0 155 563 3F BF 5
564 Operating time carrying-over times (0 to 65535) 1 0 155 564 40 C0 5 
Function
Parameter Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter Remarks
Instruction Code
Motor/Control Mode Support Table
Parameter
S-PM MM-GKR
Read Write
Extended
Speed Speed position Copy Clear All clear