124
Speed setting by external terminals
REMARKS
During Jog operation or PID control operation, the remote setting function is invalid.
CAUTION
When selecting this function, re-set the maximum speed according to the machine.
Parameters referred to
Pr.1 Maximum setting Refer to page 115
Pr.7 Acceleration time, Pr.8 Deceleration time, Pr.44 Second acceleration/deceleration time, Pr.45 Second deceleration time Refer to page 125
Pr.178 to Pr.184 (input terminal function selection) Refer to page 138
Setting speed is "0"
Even when the remotely-set speed
is cleared by turning ON the RL
(clear) signal after turn OFF (ON)
of both the RH and RM signals, the
drive unit operates at the remotely-
set speed stored in the last
operation if power is reapplied
before one minute has elapsed
since turn OFF (ON) of both the RH
and RM signals
When the remotely-set speed is
cleared by turning ON the RL
(clear) signal after turn OFF (ON)
of both the RH and RM signals, the
drive unit operates at the speed in
the remotely-set speed cleared
state if power is reapplied after one
minute has elapsed since turn OFF
(ON) of both the RH and RM
signals.
Clear (RL)
Acceleration (RH)
Forward rotation (STF)
Rotation speed (r/min)
ON
Power supply
ON
ON
ON
ON
ON
Within 1 minute
Time
Remotely-set speed
stored last time
Remotely-set speed stored last time
Deceleration (RM)
OFF
Clear (RL)
Acceleration (RH)
Forward rotation (STF)
Rotation speed (r/min)
ON
Power supply
ON
ON
ON
ON
ON
More than 1 minute
Operation is performed
at the set speed 0r/min.
Remotely-set speed
stored last time
1 minute
Time
Deceleration (RM)
OFF