218
Communication operation and setting
Example) When reading the C3 (Pr.902) and C6 (Pr.904) settings from the drive unit of station 0
To read/write C3 (Pr.902) and C6 (Pr.904) after drive unit reset or parameter clear, execute from 1) again.
List of calibration parameters
[Special monitor selection No.]
Refer to page 156 for details of the monitor description.
When "0.01 to 9998" is set in Pr.37 and "01" in instruction code HFF, the data format is 6 digits (E2).
Input terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, : undetermined value)
Output terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, : undetermined value)
REMARKS
Set 65520 (HFFF0) as a parameter value "8888" and 65535 (HFFFF) as "9999".
For the instruction codes HFF, HEC and HF3, their values are held once written but cleared to zero when a drive unit reset or all
clear is performed.
Computer Send Data Drive Unit Send Data Description
1)
ENQ 00 FF 0 01 7D ACK 00 Set "H01" to the expansion link parameter.
2)
ENQ 00 EC 0 01 79 ACK 00 Set "H01" to second parameter changing.
3)
ENQ 00 5E 0 0A STX 00 0000 ETX 20 C3(Pr.902) is read. 0% is read.
4)
ENQ 00 60 0 F6 STX 00 0000 ETX 20 C6(Pr.904) is read. 0% is read.
b15 b0
RES MRS RH RM RL STR STF
b15 b0
ABC FU RUN
Parameter Name
Instruction Code
Read
Write
Extended
C2 (902) Terminal 2 speed setting bias speed 5E DE 1
C3 (902) Terminal 2 speed setting bias 5E DE 1
125 (903) Terminal 2 speed setting gain speed 5F DF 1
C4 (903) Terminal 2 speed setting gain 5F DF 1
C5 (904) Terminal 4 speed setting bias speed 60 E0 1
C6 (904) Terminal 4 speed setting bias 60 E0 1
126 (905) Terminal 4 speed setting gain speed 61 E1 1
C7 (905) Terminal 4 speed setting gain 61 E1 1
Data Description Unit
H01
Rotation speed/output frequency/
machine speed
1/0.01Hz/0.001
H02 Output current 0.01A
H03 Output voltage 0.1V
H05
Rotation speed setting/frequency setting/
machine speed setting
1/0.01Hz/0.001
H08 Converter output voltage 0.1V
H09 Regenerative brake duty 0.1%
H0A
Electronic thermal relay function load
factor
0.1%
H0B Output current peak value 0.01A
H0C Converter output voltage peak value 0.1V
H0E Output power 0.01kW
H0F Input terminal status
H10 Output terminal status
H13 Position pulse
H14 Cumulative energization time 1h
H17 Actual operation time 1h
H18 Motor load factor 0.1%
H19 Cumulative power 1kWh
H1A
Position command
[before electronic gear] (lower 4 digits)
H1B
Position command
[before electronic gear] (upper 4 digits)
H1C
Current position
[before electronic gear] (lower 4 digits)
H1D
Current position
[before electronic gear] (upper 4 digits)
H1E
Droop pulse
[after electronic gear] (lower 4 digits)
H1F
Droop pulse
[after electronic gear] (upper 4 digits)
H24 Ideal speed command r/min
H25 Speed command r/min
H34 PID set point 0.1%
H35 PID measured value 0.1%
H36 PID deviation 0.1%
H3D Motor thermal load factor 0.1%
H3E Drive unit thermal load factor 0.1%
H3F Cumulative power 2 0.01kWh
Data Description Unit