Mitsubishi Electronics BNP-C3040D Welder User Manual


 
3. Setup
3 - 69
M60S
Series
No.
Abbrev. Parameter name Details
Setting range
(Unit)
3059 sptc6
Spindle synchro-
nization multi-step
acceleration/
deceleration
changeover
speed 6
Set the spindle speed for changing the 6th step's
acceleration/deceleration time constant.
0 to 99999
(r/min)
3060 sptc7
Spindle synchro-
nization multi-step
acceleration/
deceleration
changeover
speed 7
Set the spindle speed for changing the 7th step's
acceleration/deceleration time constant.
0 to 99999
(r/min)
3061 spdiv1
Magnification for
time constant
changeover
speed 1
Set the acceleration/deceleration time constant between the spindle
synchronization multi-step acceleration/deceleration changeover speed
1 (sptc1) to the spindle synchronization multi-step acceleration/
deceleration changeover speed 2 (sptc2) as a magnification in respect to
the spindle synchronization acceleration/deceleration time constant
(spt).
0 to 127
3062 spdiv2
Magnification for
time constant
changeover
speed 2
Set the acceleration/deceleration time constant between the spindle
synchronization multi-step acceleration/deceleration changeover speed
2 (sptc2) to the spindle synchronization multi-step
acceleration/deceleration changeover speed 3 (sptc3) as a
magnification in respect to the spindle synchronization
acceleration/deceleration time constant (spt).
0 to 127
3063 spdiv3
Magnification for
time constant
changeover
speed 3
Set the acceleration/deceleration time constant between the spindle
synchronization multi-step acceleration/deceleration changeover speed
3 (sptc3) to the spindle synchronization multi-step
acceleration/deceleration changeover speed 4 (sptc4) as a
magnification in respect to the spindle synchronization
acceleration/deceleration time constant (spt).
0 to 127
3064 spdiv4
Magnification for
time constant
changeover
speed 4
Set the acceleration/deceleration time constant between the spindle
synchronization multi-step acceleration/deceleration changeover speed
4 (sptc4) to the spindle synchronization multi-step
acceleration/deceleration changeover speed 5 (sptc5) as a
magnification in respect to the spindle synchronization
acceleration/deceleration time constant (spt).
0 to 127
3065 spdiv5
Magnification for
time constant
changeover
speed 5
Set the acceleration/deceleration time constant between the spindle
synchronization multi-step acceleration/deceleration changeover speed
5 (sptc5) to the spindle synchronization multi-step
acceleration/deceleration changeover speed 6 (sptc6) as a
magnification in respect to the spindle synchronization
acceleration/deceleration time constant (spt).
0 to 127
3066 spdiv6
Magnification for
time constant
changeover
speed 6
Set the acceleration/deceleration time constant between the spindle
synchronization multi-step acceleration/deceleration changeover speed
6 (sptc6) to the spindle synchronization multi-step
acceleration/deceleration changeover speed 7 (sptc7) as a
magnification in respect to the spindle synchronization
acceleration/deceleration time constant (spt).
0 to 127
3067 spdiv7
Magnification for
time constant
changeover
speed 7
Set the acceleration/deceleration time constant for the spindle
synchronization multi-step acceleration/
deceleration changeover speed 7 (sptc7) and higher as a magnification
in respect to the spindle synchronization acceleration/deceleration time
constant (spt).
0 to 127
3068 symtm1
Phase
synchronization
start confirmation
time
Set the time to confirm that synchronization is attained before phase
synchronization control is started.
When "0" is set, the time will be 2 seconds. When "100" or less is set,
the time will be 100ms.
0 to 9999 (ms)
3069 symtm2
Phase
synchronization
end confirmation
time
Set the time to wait for phase synchronization control to end as the time
for the rotation speed to reach the attainment range.
When "0" is set, the time will be 2 seconds. When "100" or less is set,
the time will be 100ms.
0 to 9999 (ms)
3070 syprt
Phase
synchronization
speed
Set the fluctuation amount to change the synchronous spindle rotation
speed during phase synchronization control as the command speed and
rate.
When "0" is set, the amount will be 100%.
0 to 100 (%)
3071 (Not used.) Not used. Set to "0". 0
3072 (Not used.) Not used. Set to "0". 0