Mitsubishi Electronics BNP-C3040D Welder User Manual


 
5. Spindle Adjustment
5 - 19
bitA. In forward run indexing (WRNA)
bitB. In reverse run indexing (WRIA)
The corresponding output signal turns ON while forward run indexing (WRN) or reverse run
indexing (WRI) is input to the spindle drive unit.
bitC. In orientation start command signal (ORCA)
This signal turns ON while the orientation start command (ORC) is input to the spindle drive unit.
bit D. L coil selected (LCSA)
This signal turns ON while the L coil selection signal (LCA) is input to the spindle drive unit.
<<For MDS-C1-SP>>
bitE. In sub-motor selection (MSA)
This signal turns ON when selecting sub-motor with 1-drive unit 2-motor specification.
<<For MDS-C1-SPM>>
bitE. In M coil selection (MCSA)
This signal turns ON when selecting medium-speed coil in case of using the medium-speed coil.