Mitsubishi Electronics BNP-C3040D Welder User Manual


 
5. Spindle Adjustment
5 - 9
(3) Spindle control input 3
Name Details
F E D C B A 9 8 7 6 5 4 3 2 1 0
PCHG
MS LCS ORC WRI WRN SRI SRN GR2 GR1 SC5 SC4 SC3 SC2 SC1
bit Details
0
SC1
Spindle control mode selection command 1
1
SC2
Spindle control mode selection command 2
2
SC3
Spindle control mode selection command 3
3
SC4
Spindle control mode selection command 4
4
SC5
Spindle control mode selection command 5
5
GR1
Gear selection command 1
6
GR2
Gear selection command 2
7
8
SRN
Forward run start command
9
SRI
Reverse run start command
A
WRN
Indexing forward run command
B
WRI
Indexing reverse run command
C
ORC
Orientation start command
D
LCS
L coil selection command (When using coil changeover motor)
MS
<<For MDS-C1-SP>>
Sub-motor selection command (for 1-drive unit 2-motor changeover)
E
MCS
<<For MDS-C1-SPM>>
M coil selection command (when using coil changeover motor)
F
PCHG
Position changeover mode selection
Spindle control input 3
bit0. Spindle control mode selection command 1 (SC1)
bit1. Spindle control mode selection command 2 (SC2)
bit2. Spindle control mode selection command 3 (SC3)
bit3. Spindle control mode selection command 4 (SC4)
bit4. Spindle control mode selection command 5 (SC5)
SC5 SC4 SC3 SC2 SC1 Control mode
0 0 0 * *
0 0 1 * *
Speed control
0 1 0 * * Synchronous tap control
0 1 1 0 0 C-axis control, No. 1 gain selection
0 1 1 0 1 C-axis control, No. 2 gain selection
0 1 1 1 0 C-axis control, No. 3 gain selection
0 1 1 1 1 Setting prohibited
1 0 0 * * Spindle synchronous control
1 0 1 * *
1 1 0 * *
1 1 1 * *
Setting prohibited
(Note) The asterisk indicates 1 or 0.