5. Spindle Adjustment
5 - 5
(3) Control signal output (Data No. 80 to 87)
A hexadecimal display is converted into a decimal and output. The method of calculating the
magnification is the same as (2). The status cannot be output for each bit, so output the status for
all 16 bits.
(Example) Orientation indexing control
With orientation indexing control, the following operations of the "Control output 4" can be
observed as shown on the right:
bit4: Orientation completed
bit7: Indexing positioning completed
Note that the weight of the D/A output differs for each bit.
Orientation indexing control sequence output
Orientation start
Orientation speed
Motor speed
Time
Control output 4
5[V]
Orientation time
Orientation
complete
0
10[V]
5
Indexing time
Indexing
complete