Mitsubishi Electronics BNP-C3040D Welder User Manual


 
3. Setup
3 - 103
<For MDS-C1-SP/SPH/SPX/SPHX>
No. Abbr. Parameter name Details
Setting range
(Unit)
Standard
setting
SP257
to
SP320
Motor constant
(H coil)
This parameter is valid only in the following two
conditional cases:
(a) In case that SP034 (SFNC2)/bit0=1
and SP034 (SFNC2)/bit2=0
Set the motor constants when using a special motor,
not described in the SP040 (MTYP) explanation and
when not using the coil changeover motor.
(b) In case that SP034 (SFNC2)/bit0=1
and SP034 (SFNC2)/bit2=1
Set the motor constant of the H coil of the coil
changeover motor.
(Note) It is not allowed for the user to change the setting.
(HEX setting)
0000 to FFFF 0000
SP321
to
SP384
Motor constant
(L coil)
This parameter is valid only in the following conditional
case:
(a) In case that SP034 (SFNC2)/bit0=1
and SP034 (SFNC2)/bit2=1
Set the motor constant of the L coil of the coil
changeover motor.
(Note) It is not allowed for the user to change the setting.
(HEX setting)
0000 to FFFF 0000
All motor constant parameters are validated with the NC power turned ON again.
<For MDS-C1-SPM>
No. Abbr. Parameter name Details
Setting range
(Unit)
Standard
setting
SP257
to
SP296
SP312
to
SP320
Motor constant
(H coil)
This parameter is valid only in the following two
conditional cases:
(a) In case that SP034 (SFNC2)/bit0=1
and SP034 (SFNC2)/bit2=0
Set the motor constants when using a special motor,
not described in the SP040 (MTYP) explanation and
when not using the coil changeover motor.
(b) In case that SP034 (SFNC2)/bit0=1
and SP034 (SFNC2)/bit2=1
Set the motor constant of the H coil of the coil
changeover motor.
(Note) It is not allowed for the user to change the setting.
(HEX setting)
0000 to FFFF 0000
SP297
to
SP311
SP363
to
SP375
Motor constant
(M coil)
This parameter is valid only in the following conditional
case:
(a) In case that SP034 (SFNC2)/bit0=1
and SP034 (SFNC2)/bit2=1
Set the motor constant of the M coil of the coil
changeover motor.
(Note) It is not allowed for the user to change the setting.
(HEX setting)
0000 to FFFF 0000
SP321
to
SP362
SP376
to
SP384
Motor constant
(L coil)
This parameter is valid only in the following conditional
case:
(a) In case that SP034 (SFNC2)/bit0=1
and SP034 (SFNC2)/bit2=1
Set the motor constant of the L coil of the coil
changeover motor.
(Note) It is not allowed for the user to change the setting.
(HEX setting)
0000 to FFFF 0000
All motor constant parameters are validated with the NC power turned ON again.