Mitsubishi Electronics BNP-C3040D Welder User Manual


 
3. Setup
3 - 80
No. Abbr. Parameter name Details
<For MDS-C1-SPM>
FEDCBA98765 4 3 2 10
XFzs
pl80 sdt2 vfbs orm tdn plg2 pftm alty
bit Meaning when set to 0 Meaning when set to 1 Standard
0alty
Deceleration stop during special
alarm invalid
Deceleration stop during special
alarm valid
0
1 0
2 pftm
Encoder feedback serial
communication invalid
Encoder feedback serial
communication valid
0
3plg2
Semi-closed pulse output signal×2
invalid
Semi-closed pulse output signal×2
valid
0
SP038 SFNC6* Spindle function 6
4 tdn This is used by Mitsubishi. Set to "0" unless particularly designated. 0
5 0
6 orm Orientation start memo invalid Orientation start memo valid 0
7 vfbs This is used by Mitsubishi. Set to "0" unless particularly designated. 0
8 sdt2 (Follows SP038/bitC setting)
Set output 2 to 2nd speed detection
output
0
9 pl80 MHE90K detector's 180 wave PLG 180 wave PLG other than MHE90K 0
A 0
B 0
CXFzs
Set output 2 to MP scale low (L)
speed mode
Set output 2 to zero speed output 0
D 0
E 0
F 0
(Note) Set 0 if there is no particular explanation for the bit.